EasyManua.ls Logo

Zoomlion RT60 - Page 63

Default Icon
173 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
RT60 Rough Terrain Crane 06 - 8
Note
The switch is the master power to the COOL function and must be ON (HI,
MID, LOW) for the COOL function to operate.
(3) HEAT mode
Turn on the A/C FAN SPEED / MASTER SWITCH (1) after the engine is
started:
Set the A/C FAN SPEED / MASTER SWITCH (1) to blow air.
RESULT: -
The FAN POWER INDICATOR (red) illuminates.
Push down the CAB HEATER POWER SWITCH on the dash.
RESULT:
-
The heater is ON.
Turn the A/C FAN SPEED / MASTER SWITCH (1) counter-clockwise
between 3 fan speed (HI, MID, LOW) to get the correct temperature.
Do not disassemble an A/C system that is in the Warranty Period
without consent from the A/C manufacturer.
Examine the condition and tension of the compressor belt at a regular
interval. If necessary, adjust the tension on the belt.
You must clean the condenser at a regular interval.
You must use the same type of refrigerant and compressor oil to
complete the repairs on the A/C.
Set the FAN mode to HI when you first start to cool the cab.
Do not use the parts to repair the A/C system that are not approved by
the manufacturer.
When you use the A/C function where it is cool and has a high level of
humidity, examine the evaporator at a regular interval. In these
conditions, the evaporator freezes and causes a blockage for the air
that goes through it.
If you operate the crane in a cold area or in the winter season, set the
A/C system to ON for 10 minutes each month.
Make sure that the A/C is in the OFF mode when the engine is OFF or at
idle speed for a long time. The battery drains in these conditions.
When you move the crane a long distance at low speed, with the A/C in
the ON mode, put the transmission in a low gear. This increases the
engine RPM and decreases the load on the transmission.

Other manuals for Zoomlion RT60