1-4 
more than one port has the same lowest priority, the switch will power down the PD connected to 
the port with larger port number. 
z  manual: When the switch is close to its full load in supplying power, it will not make change to its 
original power supply status based on its priority when a new PD is added. For example: Port A has 
the priority critical. When the switch PoE is close to its full load and a new PD is now added to port 
A, the switch just gives a prompt that a new PD is added and will not supply power to this new PD. 
After the PoE feature is enabled on the port, perform the following configuration to set the PoE 
management mode and PoE priority of a port. 
Follow these steps to set the PoE management mode and PoE priority of a port: 
To do…  Use the command…  Remarks 
Enter system view 
system-view 
— 
Set the PoE management 
mode for the switch 
poe power-management 
{ auto | manual } 
Required 
auto by default. 
Enter Ethernet port view 
interface interface-type 
interface-number 
— 
Se the PoE priority of a port 
poe priority { critical | high | 
low } 
Required 
low by default. 
 
Setting the PoE Mode on a Port 
PoE mode of a port falls into two types, signal mode and spare mode.  
z  Signal mode: DC power is carried over the data pairs (1,2,3,and 6) of category-3/5 twisted pairs. 
z  Spare mode: DC power is carried over the spare pairs (4,5,7,and 8) of category-3/5 twisted pairs. 
Currently, Switch 4200G does not support the spare mode. 
After the PoE feature is enabled on the port, perform the following configuration to set the PoE mode on 
a port. 
Follow these steps to set the PoE mode on a port: 
To do…  Use the command…  Remarks 
Enter system view 
system-view 
— 
Enter Ethernet port view 
interface interface-type 
interface-number 
— 
Set the PoE mode on the port 
to signal 
poe mode signal 
Optional 
signal by default. 
 
Configuring the PD Compatibility Detection Function 
After the PD compatibility detection function is enabled, the switch can detect the PDs that do not 
conform to the 802.3af standard and supply power to them. 
After the PoE feature is enabled, perform the following configuration to enable the PD compatibility 
detection function. 
Follow these steps to configure the PD compatibility detection function: