104 Installation
syd-0210/1.7 – I7.9 – 12.2009
Rating examples
Example 1:
Office 45 with one expansion keypad (EKP)
Maximal power requirements as per Tab. 39: 1320 mW
Fig. 48 indicates:
Maximum line length for a wire diameter of 0.4 mm: 770 m
Maximum line length for a wire diameter of 0.5 mm: 1200 m
Maximum line length for a wire diameter of 0,6 mm: 1200 m
Example 2:
One Office 35 and one Office 45 with one alpha keyboard each
Power requirements as per Tab. 39: 1800 mW.
Fig. 48 indicates:
Maximum line length for a wire diameter of 0.4 mm: 560 m
Maximum line length for a wire diameter of 0.5 mm: 880 m
Maximum line length for a wire diameter of 0,6 mm: 1200 m
Example 3:
Evaluation of an existing line installation
Line diameter: 0.5 mm
Loop resistance: 120 Ω
Fig. 48 indicates:
Line length: 660 m
Power available: 2120 mW