Ascotel® IntelliGate® 150/300 as of I7.9
78 Installation
syd-0210/1.7 – I7.9 – 12.2009
Notes
The ODAB options card must be fitted to slot IC2 (A150) or slot IC4
(A300) if it is to be used for connecting a door intercom (see "Equip-
ment on the ODAB options card", page 113).
The AD2 terminal cards EAD4V and EAD4C cannot be fitted to slot IC4
of an A300 due to their mechanical dimensions.
4. 5. 2 Wiring Adapter
Wiring adapters are used to route the interfaces of the interface cards to the RJ45
sockets on the front panel and are fitted to slots WA1…WA4. Slot WA0 is equipped
only in combination with the LAN switch module SM-LAN8. Slots WA3 and WA4 are
to be found only on the A300 (see also Fig. 8).
The table below provides an overview of the combinations of wiring adapters and
interface cards. Unless specified otherwise, the corresponding wiring adapter is in-
cluded in the equipment supplied with each interface card.
Tab. 22 Combinations of wiring adapters / interface cards
Wiring Adapter Interface card
Plug-in
orienta-
tion
Port number
X.1 X.2 X.3 X.4
WA-TS0 TIC-4TS TTTT T T T T
TIC-4TS STTT S T T T
TIC-2TS TTTT T T
TIC-2TS STTT S T
ESST-2
1)2)
STTT S T
WA-TS1 TIC-4TS
1)
SSTTSSTT
TIC-4TS
1)
SSST S S S T
TIC-2TS
1)
SSTTSS–
TIC-2TS
1)
SSST S S
ESST-2
1)2)
SSTTSS–
ESST-2
1)2)
SSST S S
ODAB SSTT I/O 1.2 I/O 3,4 ab/Door