Ascotel® IntelliGate® 150/300 as of I7.9
Operation and Maintenance 191
syd-0210/1.7 – I7.9 – 12.2009
6. 6 Operations supervision
6. 6. 1 Event message concept
The PBX generates an event message every time an event or error occurs. The
event tables in the Fault & Maintenance Manager are used to specify how often an
event message of a particular type may be generated over a given time period be-
fore the event message is sent to the allocated signal destinations.
The Fault & Maintenance Manager has 4 event tables that can be allocated to 4 sig-
nal destinations:
F = Frequency
T = Time period
Fig. 76 Distribution principle for an event message
1
Event
tables
Signal
destinations
Terminal
External signal
destination
Local signal
destination
• PC with SEM on
TA / ISDN Gateway
• System terminal
with display in
message group
• Printer / PC with
SEM on V.24 Main-
board / PA
• PC with SEM on
TA / ISDN Gateway
• PC with SEM an
Ethernet interface
Event message
Event log
• AIMS Fault & Main-
tenance Manager
• System Assistant
Office 45
Event type H Z
2
Event type H Z
3
Event type H Z
4
Event type H Z
haz1191aaena0