EasyManua.ls Logo

Aastra Ascotel IntelliGate 300 - Component Mounting Rules

Aastra Ascotel IntelliGate 300
228 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Ascotel® IntelliGate® 150/300 as of I7.9
82 Installation
syd-0210/1.7 – I7.9 – 12.2009
4. 5. 5 Component mounting rules
The component mounting rules mentioned in the previous chapters are listed here
in an overview:
In principle the interface cards can be used in all the card slots.
Exceptions:
The AD2 terminal cards EAD4V and EAD4C cannot be fitted to slot IC4 of an
A300 due to their mechanical dimensions.
If the ODAB options card is used to connect a door intercom, it must be fitted
to slot IC2 (A150) or slot IC4 (A300).
If the ODAB options card is used to control switch group positions and exter-
nal devices, it must be fitted to slot IC1 (A150) or slot IC1, 2 or 3 (A300).
DSP modules are stackable and must always be fitted to slot SM1. Slot SM2 on
the A300 basic system is provided for the systems future expansions.
On the ESST-2 terminal card the jumper must always be fitted in position T (see
Fig. 28).
The LAN switch module uses two neighbouring wiring adapter slots. If LAN
switch modules are fitted, only AD2 terminal cards can still be fitted to the corre-
sponding card slots.
1)
The preferred slots for a LAN switch module are slots WA0 and WA1. This means
that there is always at least one slot still available for other interface cards be-
sides AD2.
The interfaces are enabled sequentially when the system is started up. The fol-
lowing rules apply:
The number of interfaces actually enabled is determined in each case by the
system limits (see "System Limits", page 43). If a limit value is reached, all the
interface cards or all the interfaces of the last card may not be enabled.
The interfaces are enabled in accordance with their designation, starting with
the lower designations. This means that the terminal interfaces on the main-
board are always enabled before those on the interface cards.
1)
Not allowed in Australia