Technical data 69
Materials
Environmental limits
IEC compliance
Enclosure PC/ABS
Packaging Cardboard
Screen Polycarbonate
Disposal Do not dispose the control panel with municipal waste.
Check the local regulations for disposal of electronic products.
See also, drive related Recycling instructions and environmental information.
Operation Storage Transportation
Installation site altitude 4000 m (13123 ft.) - -
Air temperature -20 °C to +55 °C
(-4 °F to 131 °F)
-40 °C to +70 °C
(-40 °F to 158 °F)
-40 °C to +70 °C
(-40 °F to 158 °F)
Relative humidity 95% (non-condensing)
Temperature inside the panel -20 °C to +70 °C
(-4 °F to 158 °F)
-25 °C to +70 °C
(-13 °F to 158 °F)
-
Note: Accuracy of real time clock is not good at very high and very low temperatures.
DMS documents: 3AXD00000587751,
3AXD10000371905
Operation Transportation
Contamination levels
(IEC 60721-3-3, IEC 60721-3-2,
IEC 60721-1-3-1)
3C3
Sinusoidal vibration 61800-5-1 ed 2.
EN 60082-2-6 test Fc (1g)
class 2M3 in acc. with
EN 60082-2-6
Shock class 3M4 in acc. with
EN 60062-2-27
class 2M2 in acc. with
EN 60082-2-27
Free fall IEC-60068-2-32, drop height
1 m. (3.3 ft.)
-
EMC compliance
(EN 61800-3: 2004 +A1: 2012)
IEC 61000-4-2, IEC 61000-4-3,
IEC 61000-4-4, IEC 61000-4-6
-
DMS documents: 3AXD00000587751,
3AXD10000371905