EasyManua.ls Logo

ABB ACS1000 - 11.6.12 Replacing a Redundant Fan

ABB ACS1000
186 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
11 PREVENTIVE AND CORRECTIVE MAINTENANCE
3BHS213401 E01 REV H ACS1000 AIR-COOLED USER MANUAL 176/184
11.6.11.1 Installing the non-redundant fan
1. Check the mounting supports (1 in Fig. 11-11).
- If they are damaged, replace them.
- If they can be re-used, attach them to the new fan.
2. On both sides of the fan, orientate the groove of the mounting supports (2 in Fig. 11-11)
towards the back of the cabinet.
Figure 11-11: Installing the non-redundant fan
3. Check that all screws are properly fastened.
4. Install the new fan in reverse order of removal.
11.6.12 Replacing a redundant fan
The estimated working time to replace a redundant fan is approximately 1 hour.
1. Mounting supports
2. Groove
3. 1/4”
4. 10 mm
1
2
3
4
For information on inspection and replacement intervals, see "ACS1000 preventive
maintenance schedule" [1].

Table of Contents