Maintenance
84
Replacing the capacitor pack (R8)
1. Remove the upper front covers and disconnect the control panel cable. Remove
the side plate equipped with the control panel mounting slot.
2. Disconnect the discharging resistor wires.
3. Undo the fastening screws.
4. Lift the capacitor pack out.
5. Install the new capacitor pack in reverse order to the above.
3
3
2
2
M10
M6
2 pcs
M6x12 combi screw
3
3
3
3
3
4
At the rear side (view from
below)
2 pcs in
690 V
units
2
3