102 Parameters
04
04 Appl values
Process and counter values.
04.01 Process act1 Process feedback 1 for the process PID controller. 100 = 1 unit
04.02 Process act2 Process feedback 2 for the process PID controller. 100 = 1 unit
04.03 Process act Final process feedback after process feedback selection and
modification.
100 = 1 unit
04.04 Process PID err Process PID error, i.e. difference between PID setpoint and
feedback.
10 = 1 unit
04.05 Process PID out Output of the process PID controller. 10 = 1 unit
04.06 Process var1 Process variable 1. See parameter group 35 Process
variable.
1000 = 1
04.07 Process var2 Process variable 2. See parameter group 35 Process
variable.
1000 = 1
04.08 Process var3 Process variable 3. See parameter group 35 Process
variable.
1000 = 1
04.09 Counter ontime1 Reading of on-time counter 1. See parameter 44.01 Ontime1
func.
1 = 1 s
04.10 Counter ontime2 Reading of on-time counter 2. See parameter group 44.05
Ontime2 func.
1 = 1 s
04.11 Counter edge1 Reading of rising edge counter 1. See parameter group 44.09
Edge count1 func.
1 = 1
04.12 Counter edge2 Reading of rising edge counter 2. See parameter group 44.14
Edge count2 func.
1 = 1
04.13 Counter value1 Reading of value counter 1. See parameter group 44.19 Val
count1 func.
1 = 1
04.14 Counter value2 Reading of value counter 2. See parameter group 44.24 Val
count2 func.
1 = 1
No. Name/Value Description FbEq