218 Parameters
56.03 Signal3 param Selects the third signal to be displayed on the optional control
panel. The default signal is 01.06 Motor torque.
00.00 … 255.255 3rd signal to be displayed. -
56.04 Signal1 mode Defines the way the signal selected by parameter 56.01
Signal1 param is displayed on the optional control panel.
Disabled Signal not displayed. Any other signals that are not disabled
are shown together with their respective signal name.
-1
Normal Shows the signal as a numerical value followed by unit. 0
Bar Shows the signal as a horizontal bar. 1
Drive name Shows the drive name. (The drive name can be set using the
DriveStudio PC tool.)
2
Drive type Shows the drive type. 3
56.05 Signal2 mode Defines the way the signal selected by parameter 56.02
Signal2 param is displayed on the optional control panel.
Disabled Signal not displayed. Any other signals that are not disabled
are shown together with their respective signal name.
-1
Normal Shows the signal as a numerical value followed by unit. 0
Bar Shows the signal as a horizontal bar. 1
Drive name Shows the drive name. (The drive name can be set using the
DriveStudio PC tool.)
2
Drive type Shows the drive type. 3
56.06 Signal3 mode Defines the way the signal selected by parameter 56.03
Signal3 param is displayed on the optional control panel.
Disabled Signal not displayed. Any other signals that are not disabled
are shown together with their respective signal name.
-1
Normal Shows the signal as a numerical value followed by unit. 0
Bar Shows the signal as a horizontal bar. 1
Drive name Shows the drive name. (The drive name can be set using the
DriveStudio PC tool.)
2
Drive type Shows the drive type. 3
57
57 D2D
communication
Configuration of drive-to-drive communication. See also
section Drive-to-drive link on page 61.
57.01 Link mode Activates the drive-to-drive connection.
Disabled Drive-to-drive connection disabled. 0
Follower The drive is a follower on the drive-to-drive link. 1
Master The drive is the master on the drive-to-drive link. Only one
drive can be the master at a time.
2
57.02 Comm loss func Selects how the drive acts when an erroneous drive-to-drive
configuration or a communication break is detected.
No Protection not active. 0
Alarm The drive generates an alarm. 1
Fault The drive trips on a fault. 2
No. Name/Value Description FbEq