94 Parameters
Parameter listing
No. Name/Value Description FbEq
01
01 Actual values
Basic signals for monitoring of the drive.
01.01 Motor speed rpm Filtered actual speed in rpm. The used speed feedback is
defined by parameter 19.02 Speed fb sel. The filter time
constant can be adjusted using parameter 19.03 MotorSpeed
filt.
100 = 1 rpm
01.02 Motor speed % Actual speed in percent of the motor synchronous speed. 100 = 1%
01.03 Output frequency Estimated drive output frequency in Hz. 100 = 1 Hz
01.04 Motor current Measured motor current in A. 100 = 1 A
01.05 Motor current % Motor current in percent of the nominal motor current. 10 = 1%
01.06 Motor torque Motor torque in percent of the nominal motor torque. See also
parameter 01.29 Torq nom scale.
10 = 1%
01.07 Dc-voltage Measured intermediate circuit voltage. 100 = 1 V
01.08 Encoder1 speed Encoder 1 speed in rpm. 100 = 1 rpm
01.09 Encoder1 pos Actual position of encoder 1 within one revolution. 100000000 =
1rev
01.10 Encoder2 speed Encoder 2 speed in rpm. 100 = 1 rpm
01.11 Encoder2 pos Actual position of encoder 2 within one revolution. 100000000 =
1rev
01.12 Pos act Actual position of encoder 1 in revolutions. 1000 = 1 rev
01.13 Pos 2nd enc Scaled actual position of encoder 2 in revolutions. 1000 = 1 rev
01.14 Motor speed est Estimated motor speed in rpm. 100 = 1 rpm
01.15 Temp inverter Estimated temperature of drive heatsink in percent of fault
limit.
10 = 1%
01.16 Temp brk chopper Brake chopper IGBT temperature in percent of fault limit. 10 = 1%
01.17 Motor temp1 Measured temperature of motor 1 in degrees Celsius. 10 = 1 °C
01.18 Motor temp2 Measured temperature of motor 2 in degrees Celsius. 10 = 1 °C
01.19 Used supply volt Either the nominal supply voltage defined by parameter 47.04
Supply voltage, or, if auto-identification is enabled by
parameter 47.03 SupplyVoltAutoId, the automatically
determined supply voltage.
10 = 1 V
01.20 Brake res load Estimated temperature of the braking resistor. The value is
given in percent of the temperature the resistor reaches when
loaded with the power defined by parameter 48.04 Br power
max cnt.
1 = 1%
01.21 Cpu usage Microprocessor load in percent. 1 = 1%
01.22 Power inu out Drive output power in kW or hp, depending on setting of
parameter 16.17 Power unit.
100 = 1 kW
or hp
01.23 Motor power Measured motor power in kW or hp, depending on setting of
parameter 16.17 Power unit.
100 = 1 kW
or hp
01.24 kWh inverter Amount of energy that has passed through the drive (in either
direction) in kilowatt-hours.
1 = 1 kWh
01.25 kWh supply Amount of energy that the drive has taken from the AC supply
in kilowatt-hours.
1 = 1 kWh
01.26 On-time counter On-time counter. The counter runs when the drive is
powered. Can be reset using the DriveStudio PC tool.
1 = 1 h