EasyManua.ls Logo

ABB ACS850-04 - 32-Bit Integer Bit Pointers

ABB ACS850-04
296 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Additional parameter data 239
32-bit integer bit pointers
When a bit pointer parameter is connected to value 0 or 1, the format is as follows:
When a bit pointer parameter is connected to a bit value of another parameter, the
format is as follows:
When a bit pointer parameter is connected to a solution program, the format is as
follows:
Note: Bit pointer parameters connected to a solution program are read-only via
fieldbus.
Bit
30…31 16…29 0
Name Source type Not in use Value
Value 0-01
Description Bit pointer is connected
to 0/1.
- 0 = False, 1 = True
Bit
30…31 24…29 16…23 8…15 0…7
Name Source type Not in use Bit sel Group Index
Value 1 - 0…31 2…255 1…255
Description Bit pointer is
connected to
signal bit
value.
- Bit selection Group of
source
parameter
Index of
source
parameter
Bit
30…31 24…29 0…23
Name Source type Bit sel Address
Value 203102
23
Description Bit pointer is connected
to solution program.
Bit selection Relative address of
solution program
variable