72 Program features
Settings
Parameter group 13 Analogue inputs (page 119).
Programmable analog outputs
The drive has two current analog outputs. Each output can be filtered, inverted and
scaled. The number of analog outputs can be increased by using FIO-xx I/O
extensions.
Settings
Parameter group 15 Analogue outputs (page 139).
Programmable digital inputs and outputs
The drive has six digital inputs, a digital start interlock input, and two digital input/
outputs.
One digital input (DI6) doubles as a PTC thermistor input. See section Thermal motor
protection on page 76.
One of the digital input/outputs can be used as a frequency input, one as a frequency
output.
The number of digital inputs/outputs can be increased by using FIO-xx I/O
extensions.
Settings
Parameter group 14 Digital I/O (page 126).
Programmable relay outputs
The drive has three relay outputs. The signal to be indicated by the outputs can be
selected by parameters.
Relay outputs can be added by using FIO-xx I/O extensions.
Settings
Parameter group 14 Digital I/O (page 126).
Programmable protection functions
Start interlock (parameter 10.20)
The parameter selects how the drive reacts to loss of start interlock signal (DIIL).