8-6 Keypad and Programming 3AXD50000011888
8.2.3 Status LED
The control panel has a status LED that indicates if there are any faults or warnings present. The table below shows the
meaning of the LED indications.
Table 8-4 LED Indications
Green, Continuous The drive is functioning normally.
Green, Flickering
Data is transferred between the PC tool and drive through the USB connection
of the control panel.
Green, Blinking
There is an active warning in the drive.
Red, Continuous There is an active fault in the drive.
For further information on fault and warning indications, see Chapter 13, Troubleshooting.
8.2.4 USB Connector
The USB connector is used for connecting the control panel to a PC. When connected, the control panel acts as an USB
adapter for data transfer between the PC tool and the drive. It is also possible to transfer data between the PC and the
control panel through the USB connection.
8.2.5 RJ-45 Connector
The RJ-45 connector is used to electrically connect the control panel to the drive. Mechanical connection is achieved with
the clip on the top.
8.2.6 Type Code Label
The type code label contains revision information. The revision letter and the software version of the control panel are
highlighted in the image below.
Figure 8-9
8.2.7 Battery Cover
Underneath the cover there is a compartment for the battery that powers the real-time clock of the control panel.