EasyManua.ls Logo

ABB EC Titanium Series - Page 16

ABB EC Titanium Series
103 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2-6 General Information and Ratings MN448
Table 2-4 Axial Mount Motor and Drive Ratings
Type HP
Motor
Frame
Motor
Efficiency
Motor
Amps
Drive
Model
Drive Size
Drive
Input
Amps (I
1N
)
Drive
Output
Amps (I
2N
)
1-phase 100V…115V AC (+/-10%) - 3 Phase 230V Output
ECS100A1H1DF4 1 140 89.3% 2.4 ECI1A3P2 1 10.3 3.2
1-phase 200…240V AC (+/-10%) - 3 Phase 230V Output
ECS100A8H1DF4 1 140 89.3% 2.4 ECI8A7P0 1 7.1 7.0
ECS100A8H2DF4 2 140 90.7% 4.4 ECI8A7P0 1 12.5 7.0
ECS100A8H3DF4 3 140 91.4% 7.0 ECI8A7P0 1 13.3 7.0
ECS100A8H3EF4 3 180 92.8% 7.3 ECI8A7P0 1 12.7 7.0
3-phase 200…240V AC (+/-10%) - 3 Phase 230V Output
ECS100A2H1DF4 1 140 89.3% 2.4 ECI2A4P3 1 3.6 4.3
ECS100A2H2DF4 2 140 90.7% 4.3 ECI2A4P3 1 6.4 4.3
ECS100A2H3DF4 3 140 91.4% 7.0 ECI2A7P0 1 9.7 7.0
ECS100A2H3EF4 3 180 92.8% 7.3 ECI2A7P0 1 9.3 7.0
ECS100A2H5EF4 5 180 93.7% 10.5 ECI2A10P5 2 12.6 10.5
3-phase 380…480V AC (+/-10%) - 3 Phase 460V Output
ECS100A4H1DF4 1 140 89.3% 1.3 ECI4A2P2 1 1.8 2.2
ECS100A4H2DF4 2 140 90.7% 2.2 ECI4A2P2 1 3.2 2.2
ECS100A4H3DF4
3 140 91.4% 3.5 ECI4A4P1 1 4.7 4.1
ECS100A4H3EF4 3 180 92.8% 3.7 ECI4A4P1 1 4.7 4.1
ECS100A4H5EF4 5 180 93.7% 5.3 ECI4A5P8 1 7.1 5.8
ECS100A4H7EF4 7.5 180 94.0% 8.8 ECI4A9P5 2 10.0 9.5
Note: EC Titanium integrated motor and drives are factory programmed with the values for BEMF, R, Ld and Lq. If the drive
parameters have been reset to factory defaults, refer to the motor nameplate for values used to program the drive unit
(see Table 2-1 Motor Setup Parameter Listing).
I
1N
Continuous rms input current (measured value for integrated motor and drive).
I
2N
Continuous rms output current. 50% overload is allowed for one minute every ten minutes.
Maximum output current is 75% overload for 2.5 seconds of I
2N
.

Table of Contents

Related product manuals