11.2 Identifying the EC Titanium Motor Parameters
The EC Titanium Motor nameplate is located on the side of the motor and includes NEMA rating, appropriate markings,
a type designation and a serial number, which allow identication of each unit. The motor nameplate contains electrical
information necessary for proper setup of the ABB drive control.
SYNCHRONOUS RELUCTANCE MOTOR
FOR INVERTER USE ONLY
READ INSTRUCTIONS BEFORE INSTALLING.
PERMANENT MAGNET MOTOR. WHEN SHAFT IS
ROTATED, VOLTAGE WILL BE GENERATED AT
THE MOTOR TERMINALS.
LIRE LES INSTRUCTIONS AVANT L’INSTALLATION,
MOTEUR Á AIMANT PERMANENT. LORSQUE
L'ARBRE TOURNE, UNE TENSION SERA GÉNÉRÉE
AUX BORNES DU MOTEUR.
BALDOR- RELIANCE
ELECTRONICALLY PROTECTED MOTOR
FOR INDUSTRIAL USE
SHAFT GROUNDING BRUSH INSTALLED
NP3968A01C01
ABB MOTOR AND MECHANICAL INC., FORT SMITH, AR. MFG. IN U.S.A.
WARNING/AVERTISSEMENT
EC-Titanium
TM
BEARING
RATING
VOLTS
R.P.M.
SPEC.
ENCL.
CAT. NO.
CT TO HZ
FRAME
Ld (mH)
IP
DE ODE
VPWM TOCHP HZ
VT
MATCHED INV
FLA
RPM MAX
PH. CLASSHZ
BEMF VOLTS
SER.F.
NEMA NOM. EFF
INV TYP
Lq (mH)
SER#
TO HZ
PF
Rs OHM
HP
35E5247Z715G1 -
2
145T TEFC
54
460 2.2
1800
60
1.0
4000
3 F
12.95
246
91.4%
40C AMB - CONT
109.6 505.5
60
6 1
ECI14A2P2
6205 6205
133
60 60
EN/IEC60034-1;-5
LISTED
E46145
1
ECS100A4H2140FF4
2
3
5
6
9
10
8
11
7
ECI4A2P2
4
12 14
13
FERRITE ASSISTED
Zone Description
1 Catalog Number
2 General Motor Information
3 Motor Rated Amps
4 BEMF (Back EMF) Voltage
5 Motor Stator Resistance (Rs)
6 Ld (mH) Motor Inductance
7 Lq (mH) Motor q-axis Inductance
8 Motor Rated Frequency & Maximum Frequency
9 Matched Inverter Model Number
10 PM Motor Warning Information
11 Shaft Ground Provision Marking
12 QR Code for motor information
13 CE Marking
14 UL Agency Listing