254 PROFINET IO – Start-up
20 TELEGRAM TYPE Read-only. Indicates the telegram type
selected for PROFINET IO communication.
The adapter module automatically detects the
telegram type defined in the PLC.
For more information on the supported PPO
message types, see section PPO types on
page 326.
0 =
Unknown
ACS355:
FB PAR 20
ACSM1:
FBA PAR20
ACS850/ACQ810:
FBA par20
ACS880/ACS580:
Telegram type
0 = Unknown Cyclical communication between the master
and the module has not been established yet.
1 = PPO1 Not supported
2 = PPO2 Not supported
3 = PPO3 PPO3 selected
4 = PPO4 PPO4 selected
5 = PPO5 Not supported
6 = PPO6 PPO6 selected
7 = PPO7 PPO7 selected. Not supported with ACS355.
8 = ST1 ST1 selected
9 = ST2 ST2 selected. Not supported with ACS355.
21 ALARM DISABLE Disables PROFINET IO alarms.
For more information on the diagnostics and
alarm mechanism for PROFINET IO, see
section Diagnostic and alarm mechanism on
page 351.
0 =
Enabled
ACS355:
FB PAR 21
ACSM1:
FBA PAR21
ACS850/ACQ810:
FBA par21
ACS880/ACS580:
Alarm disable
0 = Enabled PROFINET IO alarms are enabled.
1 = Disabled PROFINET IO alarms are disabled.