Installation and CommissioningCustomer connections on manipulator
Product Manual IRB 640 23
3.1 Connection of extra equipment to the manipulator
Technical data for customer connections
Customer Power CP
Conductor resistance <0,5 ohm, 0,241 mm
2
Max. voltage 250 V AC
Max. current 2 A
Customer Signals CS
Conductor resistance <3 ohm, 0.154 mm
2
Max. voltage 50 V AC / DC
Max. current 250 mA
3.1.1 Connections on upper arm.
Figure 16 Customer connections on upper arm.
Signal name Customer terminal
controller, see chapter 2
for Controler.
Customer contact on
manipulator base, R1
(cable not supplied)
Customer contact
on upper arm, R3
Power supply
CPA XT6.1 R1.CP/CS.A1 R3.CP.A
CPB XT6.2 R1.CP/CS.B1 R3.CP.B
CPC XT6.3 R1.CP/CS.C1 R3.CP.C
CPD XT6.4 R1.CP/CS.D1 R3.CP.D
CPE XT6.5 R1.CP/CS.A2 R3.CP.E
CPF XT6.6 R1.CP/CS.B2 R3.CP.F
CPJ XT6.7 R1.CP/CS.C2 R3.CP.J
CPK XT6.8 R1.CP/CS.D2 R3.CP.K
CPL XT6.9 R1.CP/CS.A3 R3.CP.L
CPM XT6.10 R1.CP/CS.B3 R3.CP.M
Signals
CSA XT5.1.1 R1.CP/CS.B5 R3.CS.A
CSB XT5.1.2 R1.CP/CS.C5 R3.CS.B
R3.CP/CS
Air R1/2”