Ex relevant specifications
60 TZIDC-200, TZIDC-210, TZIDC-220 42/18-85-EN
10.3 TZIDC-220
10.3.1 FM / CSA
FM Approval
TZIDC-220 Positioner, Model V18350-a014b3cd4ef
IS/I,II,III/1/ABCDEFG/T6,T5,T4 Ta = 40 °C, 55 °C, 85 °C-901265
Entity, FISCO
Entity and FISCO Parameters
Terminals Type Groups Parameters
V
max
I
max
P
i
C
i
L
i
+11 / -12 Entity A-G 24 V 250 mA 1.2 W 2.8 nF 7.2 µH
+11 / -12 FISCO A-G 17.5 V 360 mA 2.52 W 2.8 nF 7.2 µH
+11 / -12 FISCO C-G 17.5 V 380 mA 5.32 W 2.8 nF 7.2 µH
+51 / -52 Entity A-G 16 V 20 mA - 60 nF 100 µH
+41 / -42 Entity A-G 16 V 20 mA - 60 nF 100 µH
+85 / -86 Entity A-G 30 V - - 3.7 nF < 1 µH
NI/I/2/ABCD/T6,T5,T4 Ta = 40 °C, 55 °C, 85 °C
S/II,III/2/EFG//T6,T5,T4 Ta = 40 °C, 55 °C, 85 °C
Enclosure type 4x
a = Case/Mounting – 1, 2, 3, 4, 5 or 6
b = Output/Safe protection – 1, 2, 3 or 4
c = Optional modules (shutdown) – 0 or 5
d = Optional mechanical kit for digital position feedback – 0, 1 or 2
e = Design (varnish/coding) – 1 or 2
f = Device identification label – 0, 1 or 2
TZIDC-220 Positioner, Model V18350-a012b3cd4ef
XP/I/2/CD/T6, T5, T4 TA = 82 °C
DIP/II, III/2/FG/T6, T5, T4 Ta = 82 °C
Enclosure type 4x
a = Case/Mounting – 1, 2, 3, 4, 5 or 6
b = Output/Safe protection – 1, 2, 3 or 4
c = Optional modules (shutdown) – 0 or 5
d = Optional mechanical kit for digital position feedback – 0, 1 or 2
e = Design (varnish/coding) – 1 or 2
f = Device identification label – 0, 1 or 2
CSA Certification 1555690
Explosion proof; enclosure 4X
Temperature range: -40 to 85 °C
T5, max. 85 °C ; T6, max. 70 °C
CL I; Div 1; Grp. C-D
CL II; Div 1; Grp. E-F-G
CL III
10.3.2 ATEX / GOST Russia / GOST Ukraine
10.3.2.1 Flameproof enclosure
Designation:
II 2G Ex d II C T4/T5/T6
Type Examination Test
Certificate:
DMT 02 ATEX E 029 X
Type:
TZIDC-220 Doc. 901132
Device class:
II 2G
Standards:
EN 60079-0: 2009
EN 60079-1: 2007
Electrical data
Voltage: ≤ 30 V AC/DC
A
mperage: ≤ 20 mA
Pneumatic data
Supply pressure: ≤ 6 bar
Thermal data
T4: -40 °C < T
amb
< 85 °C
T5: -40 °C < T
amb
< 80 °C
T6: -40 °C < T
amb
< 65 °C
Change from one to two column s

Table of Contents