EN - 9
CAT2 3 Product description
1 Switching point 6-8mm
2 Reset precision
± 0.04mm
3 Triggering moment
4 Lever length 300mm
5 Triggering force X, Y
Fig. 2 Technical Data
Switching point: Rotation around the Z axis 0.5° - 1°
Deflection in X and Y direction approx. 1.5°
Deflection in Z direction approx. 0.5 mm - 1 mm
Tab. 5 Triggering of the emergency-off switch
In direction: of the X axis and Y axis 10° - 14°
Z axis (depending on spring) 4 mm - 8 mm
Rotation around the Z axis (not for the
replacement of wear parts)
minimum
Tab. 6 Maximum possible deflection
with spring "S" 14 ± 2Nm
with standard spring "M" 17
± 2Nm
with spring "L" 20
± 2Nm
with spring "XL" 41
± 2Nm
Tab. 7 Triggering moment, 300 mm lever length