Ins t a ll i n g a n d co n n ec t i n g | Se t t ing t h e int e r m ed i at e s wit c hin g poi n t o f an ele c tron i c ho i st l i mi t
swi t c h
28
INSERTING THE PENDANT
CONTROL
Control cable Bayonet coupling
Emergency stop
button
Pendant control
Only with teach-in module: Insert pendant
control.
Only with teach-in module: Unlock
emergency stop button.
● The lower switching point is saved.
SETTING THE INTERMEDIATE
SWITCHING POINT OF AN
ELECTRONIC HOIST LIMIT SWITCH
ONLY FOR ELECTRONIC HOIST
LIMIT SWITCHES WITH AN
INTERMEDIATE SWITCHING POINT
This section only applies to a chain hoist with an
electronic hoist limit switch combined with a
pendant control with an “intermediate switching
point” rotary switch or a radio remote control with
an “intermediate switching point” function.
With the intermediate switching point function, any
hook position between the upper and lower
switching point can be moved to during normal
operation.
The intermediate switching point of the electronic
hoist limit switch can be set without opening the
chain hoist. This requires the supplied teach-in
module or a pendant control with teach-in button,
or an ABURemote AC receiver with teach-in.
The intermediate switching point does not need to
be reset if the chain and chain sprocket are
replaced. If the chain and chain sprocket are
replaced, only the reference point needs to be
reset. See “Exchanging the chain and chain
sprocket” page 45.