58 I
II - 5 Remote Switch Data Output
II - 5 Remote Switch Data Output
The remote switch (pendant or footswitch), or Ctrl B (sent over serial
interface), will transmit the currently displayed values in either Actual
Value or Distance-To-Go mode, whichever is currently visible.
Data output using external signals
Example 1: Linear axis with radius display X = + 41.29 mm
1 Coordinate axis
2 Equal sign
3 +/– sign
4 2 to 7 places before the decimal point
5 Decimal point
6 1 to 6 places after the decimal point
7 Unit: blank space for mm, “ for inches
8 Absolute display:
R for radius, D for diameter
Distance-to-go display:
r for radius, d for diameter
9 Carriage return
10 Blank line (Line Feed)
X
=+ 4 1 . 2 9 R <CR> <LF>
123456789 10