60 I
II - 5 Remote Switch Data Output
7 Colon
8 0 to 2 places seconds
9 Blank space
10 W for angle (in distance-to-go display: w
11 Carriage return
12 Blank line (Line Feed)
Data output using Edge Finder
In the next three examples, measured value output is started with a
switching signal from the edge finder. Printing capability can be
turned on, or off in the Job Setup parameter Measured Value Output.
Information from here is transmitted from the selected axis.
Example 4: Probing function Edge Y = –3674.4498 mm
1 Coordinate axis
2 (2) Blank Spaces
3 Colon
4 +/– sign, or Blank Space
5 2 to 7 places before the decimal point
6 Decimal point
7 1 to 6 places after the decimal point
8 Unit: blank space for mm, “ for inches
9R for Radius, D for Diameter display
10 Carriage return
11 Blank line (Line Feed)
Y
: - 3 6 7 4 . 4 4 9 8 R <CR> <LF>
12345678910 11