Technical Specifications
Note: The above performances are based on a primary flow temperature of 85°C and a domestic cold water inlet of
10°C,without the use of a thermostatic mixing valve on the domestic hot water outlet.
JUMBO JUMBO
800 1000
Code 06253901 06254001
Total capacity L 800 1000
Primary capacity L 125 160
Heating surface area m
2
4.56 5.5
Primary Pressure drop mbar 96 101
Primary flow rate L/h 7500 7800
Maximum useable input from boiler kW 100 112
Primary connections (female BSP) Ø 2" 2"
Hot water connections (male BSP) Ø 2" 2"
Dimensions
A mm 1915 2315
B mm 1020 1020
C mm 340 340
D mm 1250 1650
E mm 1020 1020
Weight empty Kg 360 380
Weight full Kg 1160 1380
Domestic Hot Water Performances
JUMBO JUMBO
800 1000
Peak flow 40°C L/10’ 1881 2265
Peak flow 45°C L/10’ 1612 1941
Peak flow 60°C L/10’ 961 1145
Peak flow 1st hour 40°C L/60’ 4270 4940
Peak flow 1st hour 45°C L/60’ 3660 4234
Peak flow 1st hour 60°C L/60’ 2124 2438
Continuous flow 40°C L/h 2868 3210
Continuous flow 45°C L/h 2458 2751
Continuous flow 60°C L/h 1395 1552
Maximum Operating Pressure
Primary: 5 bar
Secondary: 10 bar
Factory Test Pressure
Primary: 7.5 bar
Secondary: 13 bar
Maximum Operating Temperature
90°C