24
Display
code
Function Default Value
Adjust
Range
Unit Remark
CD16
ACC./DEC.
curve
0 0~1
0 : Linear
1 : S curve
CD17 Current limit 300/200 20~300/20~200 %
750W : 300%
750W : 200%
CD18 Direction limit 0 0~2
0 : CW and CCW
1 : CW only
2 : CCW only
CD19
Analog/digital
speed input
0 0~1
CD20 Reserved
CD21 Address setting 1 0~255
CD22
Transmission
speed
3 0~3
CD23
Transmission
fault treatment
3 0~3
CD24
Communicator
protocol
0 0~7
CD25
Communication
loss time detect
0.5 0.1~100.0 SEC
CD26
Communication
loss action
3 0~3
CD27
Communication
error detect
3 1~10
CD28
1
st
close loop
speed
1000
0~6000 /
0~9999
RPM
CD29
2
nd
close loop
speed
2000
0~6000 /
0~9999
RPM
CD30 Reset to default 0 0 or 1
CD34
1
st
open loop
speed
100 0~1000 0.1%
CD35
2
nd
open loop
speed
200 0~1000 0.1%