8 Operation and connection
8-1 Parameter list
23
Display
code
Function Default Value
Adjust
Range
Unit Remark
CD00 Parameter lock 0 0~1
CD01
Motor RPM &
pole selection
As model 0~4
CD02
Command
mode
1 0~7
0~3 : Close loop control
4~7 : Open loop control
CD03 Brake mode 1 0~2
0 : Rush stop without
DEC. time
1 : Stop with DEC.
time
2 : Free run to stop
CD04
Maximum
speed limited
2000/3000/6000
HX:9999
130~6000
HX:260~9999
RPM
CD05
Minimum speed
limited
0
0~6000
HX:0~9999
RPM
CD06
Speed
command
RPM/5V
2000/3000/6000
HX:9999
1000~rated speed
RPM
CD07
Speed
command
RPM/0V
0 -500~500 RPM
CD08
Acceleration
time
0.2 0.2~600.0 SEC
CD09
Deceleration
time
0.2 0.2~600.0 SEC
CD10 S curve 0.2 0.2~15.0
CD11 4~20mA 0 0~1
CD12 K
P
(P gain) As model 1~9999
mv/RPM
CD13 K
I
(I gain) As model 1~9999 ms
CD14
Hall sensor
position off set
shift
10 0~30
CD15 Display ratio 1 1~200

Related product manuals