Ex. Computer commands the address 52(34H) driver to operate
CW at 1500RPM.
1. RTU
Step 1 : write address 28=1500RPM
Computer command message :
Drive response message :
Note : Process step 2 directly if address 28 is set in
1500RPM already.
Step 2 : write address 100=1
Computer command message :
Drive response message :
50
D1
34H
D2
06H
D3
00H
D4
64H
D5
00H
D6
01H
D7
CRCL
D8
CRCH
D1
34H
D2
06H
D3
00H
D4
64H
D5
00H
D6
01H
D7
CRCL
D8
CRCH
D1
34H
D2
06H
D3
00H
D4
1CH
D5
05H
D6
DCH
D7
CRCL
D8
CRCH
D1
34H
D2
06H
D3
00H
D4
1CH
D5
05H
D6
DCH
D7
CRCL
D8
CRCH