STEP
1
2
3
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
KEYSTROKES
[-G+GG.]
cl
-w
cl
+
0008
ElIENTER)
--
q
[fllpiq
-
LJ
-b
2101[-1jIENTER]
COMMENTS
Enter horizontal connection.
Move cursor to 1,2.
Enter 1 second timer 4016 with
preset of 20 seconds and vertical
connector.
Move cursor to 1,3.
Enter coil 0007.
Move cursor to 1,4.
Enter counter 4001 with preset of 9.
4001 is sequencer register and
preset value is one more than the
number of steps.
Move cursor to 1,5.
Enter coil 0008.
Move cursor to 2,l.
Enter NC contact 0007.
Move cursor to 2,3.
Enter NC contact 0008.
Move cursor to 3,l.
Enter horizontal connector.
Move cursor to 3,2.
Enter horizontal and vertical
connectors.
Move cursor to 3,3.
Enter horizontal connector.
Move cursor to 3,4.
Enter horizontal and vertical
connector.
Move cursor to 3,5.
Enter NO contact 2101 (sequencer
step 1).
B-6
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com