7. TECHNICAL DATA
Model 0200 0240 0280 0300 0330 0350 0500 0550 0600 0650 0700 0750
Cooling capacity
HA kW
43 50 56 64 68 80
100 104 124 141 160 185
HE kW 95 99 116 131 153 179
Input power
HA kW
13,8 16,3 18,7 20,6 23,0 26,7
32,0 35,5 43,6 49,8 54,3 63,5
HE kW 34,8 38,5 47,9 54,9 61,1 69,6
Water flow rate
HA l/h
7400 8600 9549 10956 11711 13776
17118 17949 21269 24211 27556 31749
HE l/h 16390 17051 19874 22457 26270 30867
Total pressure drops
SYSTEM SIDE
HA kPa
26 37 22 29 22 31
37 39 37 48 56 67
HE kPa 343532415163
Available static pressure
Low static pressure pump
HA kPa
132 120 135 126 128 120
141 133 124 95 113 104
HE kPa 147 140 135 114 125 110
Available static pressure
High static pressure pump
HA kPa
172 160 175 165 166 159
181 173 211 181 177 224
HE kPa 186 180 223 200 192 231
Heating capacity
HA kW
46 53 60 75 80 84
106 112 137 152 173 205
HE kW 106 112 137 152 173 205
Input power
HA kW
13,1 15,3 17,5 22,0 23,6 25,3
32,1 34,5 40,6 44,9 52,8 61,4
HE kW 32,1 34,5 40,6 44,9 52,8 61,4
Water flow rate
HA l/h
7912 9116 10236 12833 13732 14526
18242 19290 23507 26146 29796 35340
HE l/h 18242 19290 23507 26146 29796 35340
Pressure drops
SYSTEM SIDE VERS.
2 PIPES
HA|HE kPa
31 42 25 39 31 34 42 45 45 56 66
83
Pressure drops
DHW SIDE/SYSTEM SIDE
HA|HE kPa131721333819313451493550
ENERGY INDEX
EER
HA
3,12 3,06 2,96 3,10 2,97 3,00
3,11 2,94 2,83 2,83 2,95 2,91
HE 2,74 2,58 2,41 2,38 2,50 2,58
COP
HA
3,50 3,46 3,41 3,40 3,38 3,33
3,30 3,25 3,37 3,39 3,28 3,34
HE 3,30 3,25 3,37 3,39 3,28 3,34
TOTAL RECOVERY
Cooling capacity
HA kW
45 52 58 68 73 86
102 110 132 147 167 200
HE kW 102 110 132 147 167 200
Recovered power
HA kW
58 67 75 88 95 111
132 142 174 193 218 261
HE kW 132 142 174 193 218 261
Total input power
HA kW
13,0 15,2 17,5 20,0 22,0 25,0
30,0 32,0 42,0 46,5 51,0 61,0
HE kW 30,0 32,0 42,0 46,5 51,0 61,0
TER - Total Efficiency Ratio W/W 7,92 7,82 7,57 7,80 7,64 7,88 7,80 7,88 7,29 7,30 7,55 7,56
Rate of water evaporation
HA l/h
7740 8944 9890 11696 12556 14792
17544 18920 22704 25198 28724 34400
HE l/h 17544 18920 22704 25198 28724 34400
Evaporator pressure drops
SYSTEM SIDE
HA kPa
30 40 24 33 26 36
39 43 42 52 61 78
HEkPa 394342526178
Recovery water flow rate
HA L/h
9976 11520 12900 15136 16340 19092
22704 24424 29928 33196 37496 44892
HE l/h 22704 24424 29928 33196 37496 44892
Recovery pressure drops
DHW SIDE/SYSTEM SIDE
HA kPa
20 27 33 46 54 33
47 55 82 78 56 80
HEkPa 475582785680
Available static pressure
Low static pressure pump
kPa 138 129 120 102 126 138 146 131 70 93 90 100
Available static pressure
High static pressure pump
kPa 176 166 157 138 166 178 201 185 122 135 135 172
PROTECTION RATING OF THE UNIT
IP 24 24 24 24 24 24 24 24 24 24 24 24
1 DHW SIDE/SYSTEM SIDE
DHW side, production of domestic hot water, in 2-pipe systems.
System side, production of hot water, in 4-pipe systems.
COOLING
Evaporator inlet water temperature 12°C
Evaporator outlet water temperature 7°C
External air temperature 35°C
Δt water 5°C
HEATING
Condenser inlet water temperature 40°C
Condenser outlet water temperature 45°C
External air temperature 7°C d.b. 6°C w.b.
Δt water 5°C
COOLING with RECOVERY
Recovery outlet water temperature 45°C
Evaporator outlet water temperature 7°C
Δt water 5°C
VERSION "°" TECHNICAL DATA
VERSION "H" TECHNICAL DATA

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AERMEC NRP 0280 and is the answer not in the manual?

AERMEC NRP 0280 Specifications

General IconGeneral
BrandAERMEC
ModelNRP 0280
CategoryHeat Pump
LanguageEnglish

Related product manuals