21Aermec cod. 5806715_00 12.01
NRP 0200-0750
EN
12. TOTAL PRESSURE DROPS 2|4 PIPE UNITS
12.1. SYSTEM SIDE COLD WATER PRODUCTION 2 PIPES
12.2. IN FUNCTIONING MODE WITH DHW SIDE RECOVERY 2 PIPES | HOT WATER PRODUCTION SYSTEM SIDE 4 PIPES
12.3. HOT WATER PRODUCTION SYSTEM INSIDE 2 PIPES
Water capacity l/h
Water capacity l/h
Water capacity l/h
kPa
kPa
kPa
Average water temperature 5 10 15 20 30 40 50
Multiplicative coefficients 1.02 1 0.98 0.97 0.95 0.93 0.91
Average water temperature 23 28 33 38 43 48 53 58
Multiplicative coefficients
1.04 1.03 1.02 1.01 1.00 0.99 0.98 0.97
Average water temperature 23 28 33 38 43 48 53 58
Multiplicative coefficients
1.04 1.03 1.02 1.01 1.00 0.99 0.98 0.97
1
2
3
4
5
6
7
8
9
10
1
2
3
4
6
5
7
8
9
10
11
12
0
20
40
60
80
100
120
140
160
180
200
0 10000 20000 30000 40000 50000 60000
NRP0200
NRP0240
NRP0280
NRP0300
NRP0330
NRP0350
NRP0500
NRP0550
NRP0600
NRP0650
11
NRP0700
12
NRP0750
1
2
3
4
5
6
7
8
9
10
11
12
0
20
40
60
80
100
120
140
160
180
200
220
240
0 10000 20000 30000 40000 50000 60000 70000 80000
1
NRP0200
2
NRP0240
3
NRP0280
4
NRP0300
5
NRP0330
6
NRP0350
7
NRP0500
8
NRP0550
9
NRP0600
10
NRP0650
11
NRP0700
12
NRP0750
1
2
3
4
5
6
7
8
9
10
11
12
1
2
3
4
5
6
7
8
9
10
11
12
0
20
40
60
80
100
120
140
160
180
200
220
240
260
0 10000 20000 30000 40000 50000 60000 70000
NRP0200
NRP0240
NRP0280
NRP0300
NRP0330
NRP0350
NRP0500
NRP0550
NRP0600
NRP0650
NRP0700
NRP0750
Evaporator inlet water temperature 7°C
Evaporator outlet water temperature 12°C
External air temperature 35°C
Average water temperature 10°C
For temperatures other than 10°C, use the corrective
factors table.
Condenser inlet water temperature 40°C
Condenser outlet water temperature 45°C
External air temperature 7°C d.b. 6°C w.b.
Average water temperature 43°C
For temperatures other than 43°C, use the corrective
factors table.
Recovery inlet water temperature 40°C
Recovery outlet water temperature 45°C
Average water temperature 43°C
For temperatures other than 43°C, use the corrective
factors table.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AERMEC NRP 0280 and is the answer not in the manual?

AERMEC NRP 0280 Specifications

General IconGeneral
BrandAERMEC
ModelNRP 0280
CategoryHeat Pump
LanguageEnglish

Related product manuals