4. FEATURES
• Refrigerant gas R410A
• Heat pump functioning with reverse
cooling cycle and defrost control
• Centrifugal type 4-speed fan:
− 4 speeds can be selected directly
(Minimum, Medium, Maximum, Tur-
bo)
− AUTO speed by which the unit au-
tomatically selects the most suitable
speed
• Rotary compressor
• Particularly quiet operation
• Microprocessor control
• Infra-red remote handset with liquid
crystal display for full control of all
appliance functions.
• Possible control via the panel on the
machine; the panel also displays
information on the operation of the
unit via a display, and icons also on
the display
• Timer for programming switch-on
and/or switch-off
• Operating mode: Cooling, Heating,
Dehumidification, Automatic and
Fan only
• Sleep programme
• Quick Cooling / Heating (TURBO)
function
• Prolonged ventilation function
(X-FAN or BLOW) is used to prevent
the formation of mould in the indoor
unit during Cooling and Dehumidifi-
cation
• Smart preheat function to avoid jets
of cold air (heating mode)
• Self-diagnosis function
• Auto-Restart function after a power
outage
• Outdoor unit defrost function
• Outdoor unit with connection for
the condensate discharge
• Washable air filter
• Double motorised fins controllable
via remote handset for vertical and
horizontal supply air, with 5 fixed or
floating positions (SWING)
• Cooling connections with flared
ends
• Easy installation and maintenance
• Automatic operating mode suitable
for the various installation environ-
ments (room, office, restaurant)
5. OPERATING LIMITS
SC1200
Indoor unit (°C) Outdoor unit (°C)
Temperature D.B. Temperature W.B. Temperature D.B. Temperature W.B.
Cooling
Nominal 27 19 35 /
Maximum 32 23 43 /
Minimum 21 15 18 /
Heating
Nominal 20 / 7 6
Maximum 27 / 24 18
Minimum 20 / -15 /
WARNING: the safety devices can lock the unit in case they are used outside of the operating limits