58.
Switc
h
bet
ween
the fastest
sw
eep
time
(0
ms)
and
200
ms
sw
eep
time
and c
hec
k
that
p
o
w
er
c
hanges
less
than
2/3
division
(

1
dB).
If the
c
hange
in
p
o
w
er
is
greater
than
2/3 division,
readjust the
A term
of the
dela
y adjustmen
t #172
for lo
wend
problems,
or
the
B
term
of
the
dela
y
adjustmen
t
#185
for
high
end
problems.
59.
On
the
syn
thesizer, press:
4
CONT
5
4
SWEEP
TIME
5
4
0
5
4
msec
5
60.
Press
4
SINGLE
5
sev
eral
times
to
initiate
sev
eral
sw
eeps.
If
a
drop
in p
ow
er
greater
than
1
division
o ccurs
when in
single
sw
eep,
increase
the
A
term
of
the
dela
y adjustmen
t
#172
to
put
the
A
term
at
the
high
end
of
the
p
eak.
(See
\Adjustmen
t
Help".)
Band
4
Multi-band
Amplifier/Multiplier
Dela
y
Compensation
(HP
83630A/40A/50A
only)
.
61.
On
the
syn
thesizer, press:
4
ST
ART
5
4
2.0
5
4
GHz
5
4
STOP
5
4
26.5
5
4
GHz
5
4
CONT
5
4
SWEEP
TIME
5
4
0
5
4
msec
5
4
MARKER
5
N
N
NN
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
NN
Marker
M3
4
20
5
4
GHz
5
(start
of
band
4)
62.
Adjust
calibration
constan
t
#173,
YTM
Bx
Dly
T
erm A4,
to
maximize
p
o
w
er
at
the
start
of
band
4.
63.
Adjust calibration
constan
t
#186,
YTM
Bx
Dly
T
erm
B4,
to
maximize
p
o
w
er
at
the
high end
of band
4.
64.
Switc
h
b
et
w
een
the
fastest
sw
eep
time
(0
ms) and
500 ms
sweep
time
and
chec
k
that
p
o
w
er
c
hanges
less
than
2/3
division
(

1
dB)
across
both
bands.
If
the c
hange is
greater than
2/3 division,
readjust
the
appropriate
dela
y
term.
65.
On
the
syn
thesizer,
press:
4
SWEEP
TIME
54
0
54
msec
5
66.
Press
4
SINGLE
5
sev
eral
times
to initiate
sev
eral
sw
eeps.
If
a
drop
in
po
wer greater than 1 division o ccurs when in single sw
eep, readjust the
appropriate dela
y term for the lo cation of the problem.
67. On
the synthesizer, press:
4
START
5
4
15
5
4
GHz
5
4
CONT
54
SWEEP TIME
54
0
54
msec
5
68. Press
4
SINGLE
5
several times to initiate
several sweeps. If a drop in p o
wer
greater than 1/3 division o ccurs when in single sw
eep, readjust the
appropriate delay term for the lo cation of the problem.
HP 8360 Adjustments
Amplifier/Multiplier Adjustments
3-47
All manuals and user guides at all-guides.com
all-guides.com

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies 83620A and is the answer not in the manual?

Agilent Technologies 83620A Specifications

General IconGeneral
BrandAgilent Technologies
Model83620A
CategoryBlower
LanguageEnglish