28.
On
the
oscilloscop e,
reset c
hannel 1
to
0.01
v
olts/division.
29. Rep
eat
steps
13
and
16
through
17
(the
oscilloscop
e
and
pulse
generator
are
already
set
up)
for
the
CW
frequencies
in
T
able 2-24.
Do
not
exceed
the
maximum
frequency of
your
synthesizer.
Record
the
video
feedthrough
(in
T
able
2-24).
T
able 2-24.
Millimeter
Band
Video
Feedthrough
Frequencies
F
requency
(GHz)
Video
F
eedthrough
(%)
23.0
28.0
35.0
45.0
30.
Record
the
w
orst
case
v
alue in
T
able
2-24
on
the
test
record.
Related
Adjustments
None
In
Case
of
Difficulty
Refer
to
the
T
r
oublesho
oting
manual.
12-38 Performance Tests
Pulse Modulation Video Feedthrough