Series N6700 User’s Guide 85
SENSe:SWEep:POINts <points>|MIN|MAX, (@<chanlist>)
SENSe:SWEep:POINts? [MIN|MAX,] (@<chanlist>)
This command defines the number of points in a measurement on
models that have measurement controls. Programmed values can
range from 1 to 4096.
The *RST value = 1024.
SENSe:SWEep:TINTerval <interval>|MIN|MAX, (@<chanlist>)
SENSe:SWEep:TINTerval? [MIN|MAX,] (@<chanlist>)
This command defines the time period between samples in seconds
on models that have measurement controls. Programmed values can
range from 0.00002048 to 40000 seconds. Values are rounded to the
nearest 20.48 microsecond increment.
The*RST value = 20.48 microseconds.
SENSe:VOLTage[:DC]:RANGe[:UPPer] <value>|MIN|MAX, (@<chanlist>)
SENSe:VOLTage[:DC]:RANGe[:UPPer]? [MIN|MAX,] (@<chanlist>)
This command selects a DC voltage measurement range on models
that have multiple ranges. The programmed value must be the
maximum voltage that you expect to measure. Units are in volts. The
instrument selects the range with the best resolution for the value
entered. When queried, the returned value is the maximum DC
voltage that can be measured on the range that is presently set.
Refer to Appendix A for the available ranges for each model.
The *RST value = the highest available range.
SENSe:WINDow[:TYPE] HANNing|RECTangular, (@<chanlist>)
SENSe:WINDow[:TYPE]? (@<chanlist>)
This command sets the window function used in DC measurement
calculations on models that have measurement controls. Select from:
HANNing A signal conditioning window that reduces errors in DC measurement
calculations in the presence of periodic signals such as AC line ripple. The
Hanning window multiplies each point in the sample by the function cosine
4
.
RECTangular A window that returns measurement calculations with no signal conditioning.
Note that neither window function alters the instantaneous voltage
or current data returned in the measurement array.
The *RST value = RECTangular.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies N6751A and is the answer not in the manual?

Agilent Technologies N6751A Specifications

General IconGeneral
BrandAgilent Technologies
ModelN6751A
CategoryPower Supply
LanguageEnglish

Related product manuals