Table Error Messages
Indication in
the display
Acoustic sig-
nal on the
wheel
Repetition
Acoustic
signal
Error description What to do
every 10
seconds
Overtemperature
of the motor.
Switch off the system and allow it to
cool down; observe the ambient tem-
perature.
every 8
seconds
Overvoltage in the battery pack; a forced
shut-down is immediately pending.
The error occurs especially when driving
down slopes with fully charged battery
pack. Drive at a slower speed.
every 10
seconds
Overvoltage of the battery pack.
The system is shut down by force.
The error occurs especially when driving
down slopes with fully charged battery
pack. Drive at a slower speed.
every 60
seconds
Undervoltage of the battery pack (< 10 %
remaining capacity), a forced shut-down is
immediately pending.
Charge the battery pack immediately.
every 10
seconds
Undervoltage of the battery pack (< 5 %
remaining capacity), a forced shut-down is
immediately pending.
Complete a ride down a slope. Charge
the battery pack immediately.
every 10
seconds
The voltage in the battery pack is no long-
er sufficient for operation, the drive was
shut down by force.
Charge the battery pack immediately.
every 10
seconds
The signal coming from the push rim is
applied longer than one wheel rotation.
A foreign object may have become
wedged in the push rim. Remove this
foreign object.
Defect in the wheel, repair required.
1 time each
time the
e-motion is
switched on
The battery pack has less than 60 % capac-
ity of a new battery.
The achievable range is significantly
reduced. Replace the battery pack
against a new one.
every 3
seconds
The charger plug is inserted in the charger
socket; the wheel turns at the same time.
Pull the charger plug from the charger
socket or stop the movement of the
wheel.