EasyManua.ls Logo

Alcatel-Lucent OmniSwitch 6250-M - Monitoring Power over Ethernet via CLI

Alcatel-Lucent OmniSwitch 6250-M
156 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installing and Managing Power over Ethernet (PoE) Monitoring Power over Ethernet via CLI
OmniSwitch 6250 Series Hardware Users Guide September 2009 page 5-11
Preliminary
9/28/09
Monitoring Power over Ethernet via CLI
To monitor current PoE statistics and settings, use the show lanpower command. The command output
displays a list of all current PoE-capable, along with the following information for each port:
Maximum power allocated to the port, in milliwatts
Actual power used by the port
Current port status
Power priority status
Power on/off status
Aggregate slot and chassis management information is also displayed. This information includes:
Maximum watts allocated to the corresponding slot
Amount of power budget remaining that can be allocated for PoE modules
Total amount of power remaining that can be allocated for additional switch functions
When entering the show lanpower command, you must include a valid slot number in the command line
syntax. For example:
-> show lanpower 1
-> show lanpower 1
Port Maximum(mW) Actual Used(mW) Status Priority On/Off Class
----+-----------+---------------+-----------+---------+------+-------
1 15400 0 Undefined Low OFF None
2 15400 0 Undefined Low OFF None
3 15400 0 Undefined Low OFF None
4 15400 0 Undefined Low OFF None
Slot 1 Max Watts 66
66 Watts Total Power Budget Remaining
66 Watts Total Power Budget Available
2 Power Supplies Available
Note. For detailed information on show lanpower command output, refer to the OmniSwitch CLI Refer-
ence Guide.

Table of Contents