EasyManua.ls Logo

Alcatel-Lucent OmniSwitch AOS Release 6 - Page 124

Alcatel-Lucent OmniSwitch AOS Release 6
346 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SNMP Overview Using SNMP
page 3-38 OmniSwitch AOS Release 6 Switch Management Guide July 2010
dot3OamEventLogTimestamp—The sysUpTime at the time of the logged event.
dot3OamEventLogOui—The OUI of the entity defining the object type. All IEEE 802.3 defined events (as
appearing in [802.3ah] except for the Organizationally Unique Event TLVs) use the IEEE 802.3 OUI of
0x0180C2. Organizations defining their own Event Notification TLVs include their OUI in the Event Notifica-
tion TLV that is reflected here.
dot3OamEventLogType—The type of event that generated this entry in the event log. When the OUI is the
IEEE 802.3 OUI of 0x0180C2, the following event types are defined: erroredSymbolEvent(1), erroredFrameP-
eriodEvent(2), erroredFrameEvent(3), erroredFrameSecondsEvent(4), linkFault(256), dyingGaspEvent(257),
criticalLinkEvent(258).
dot3OamEventLogLocation—Indicates whether this event occurred locally (local(1)), or was received from
the OAM peer via Ethernet OAM (remote(2)).
dot3OamEventLogWindowHi—The time interval, in seconds, that is used to monitor the “High” threshold
limit for this event. A notification is sent every time the threshold is exceeded during any 5-second monitoring
interval.
dot3OamEventLogWindowLo—The time interval, in seconds, that is used to monitor the “Low” threshold
limit for this event. A notification is sent every time the threshold is exceeded during any 5-second monitoring
interval.
dot3OamEventLogThresholdHi—The “High” threshold level set for the event.
dot3OamEventLogThresholdLo—The “Low” threshold level set for the event.
dot3OamEventLogValue—The value of the event when it exceeded a threshold limit.
dot3OamEventLogRunningTotal—the total number of times this event has happened since the last reset
dot3OamEventLogEventTotal—The total number of times this event has resulted in a notification.
120 dot3OamNonThresholdEvent dot3OamEvent
LogTimes-
tamp
dot3OamEvent
LogOui
dot3OamEvent
LogType
dot3OamEvent
LogLocation
dot3OamEvent
LogEvent-
Total
dot3-oam This trap is sent when a local or
remote non-threshold crossing
event is detected. A local event is
detected by the local entity,
while a remote event is detected
by the reception of an Ethernet
OAM Event Notification
OAMPDU that indicates a non-
threshold crossing event.
dot3OamEventLogTimestamp—The value of sysUpTime at the time of the logged event.
dot3OamEventLogOui—The OUI of the entity defining the object type. All IEEE 802.3 defined events (as
appearing in [802.3ah] except for the Organizationally Unique Event TLVs) use the IEEE 802.3 OUI of
0x0180C2. Organizations defining their own Event Notification TLVs include their OUI in the Event Notifica-
tion TLV that gets reflected here.
dot3OamEventLogType—The type of event that generated this entry in the event log. When the OUI is the
IEEE 802.3 OUI of 0x0180C2, the following event types are defined: erroredSymbolEvent(1), erroredFrameP-
eriodEvent(2), erroredFrameEvent(3), erroredFrameSecondsEvent(4), linkFault(256), dyingGaspEvent(257),
criticalLinkEvent(258).
dot3OamEventLogLocation—Indicates whether this event occurred locally (local(1)), or was received from
the OAM peer via Ethernet OAM (remote(2)).
dot3OamEventLogEventTotal—The total number of times this event has resulted in a notification.
No. Trap Name Objects Family Description

Table of Contents

Related product manuals