c. Use the default installation (click on Next in each Wizard screen).
d. At the end of the Wizard mode, check the Install Capi-port driver box.
4. Select AVM ISDN1 Internet (PPP over ISDN).
5. Reboot the PC.
6.2.3.4.1.3 Using Remote Access With OMC
1. Launch OMC. The OMC Welcome page is displayed.
2. Select the appropriate menu, as follows:
• the Expert menu, if you are logging in as "installer"
• the EasyPlus menu, if you are logging in as "administrator"
• the Easy menu, if you are logging in as "operator" or "attendant"
3. In the toolbar menu, click Comm.
4. Select Connect. The Communication Path window is displayed.
5. Click Modem direct, then OK.
6. Click Dialing and select AWM ISDN1 Internet (PPP over ISDN).
7. Dial the customer phone number and click OK.
8. Type in the appropriate password according to your user mode, Expert, EasyPlus or Easy.
Note:
The PC and B1 lights on the modem should light up when the connection is established.
The configuration session is open.
6.2.3.4.1.4 Remote Access to the ISDN Modem
When an ISDN modem is used, it is necessary to reserve a DDI number in the public numbering plan
to be able to establish remote access.
If  no  DDI  number  is  available,  check  whether  the  system's  ISDN  modem  access  is  in  the  default
attendant group (default group). In this case it is not necessary to keep a DDI number.
Remark:
If the modem is not currently in the attendant group, it is useful to set the Reroutdata flag to the value 01H. The
system then automatically recognizes the ISDN service corresponding to the incoming call and looks in the default
attendant group for a data terminal.
6.2.3.4.2 Remote Access By The Analog Modem
6.2.3.4.2.1 Analog Modem (recommended)
OXO Connect is equipped with an analog modem V34 for remote access through the public network.
This  modem  provides  a  point-to-point  communication  link  accessible  via  standard  LINUX  protocols
(PPP, etc.).
Its main characteristics are:
• V34 Modem
• Maximum transmission speed: 33600 bds
• Hayes protocol
In the current version of the system, the V34 "US Robotic" modem has been validated. The other types
of modems were not validated.
6.2.3.4.2.2 Installation Process of the Remote Access by Analog Modem
Follow the  procedures  described in  the  previous paragraphs, but  replace the FRITZ modem  with the
US Robotics analog modem.