0000 0011 1111 1100
4.13.2 Safety rules
4.13.2.1 Environmental protection
For an exterior installation, it is necessary to take precautions against lightning affecting the location of
the 4070 IO/EO.
4.13.2.1.1 Conditions for using lightning protection
Protection of 4070 IO/EO against lightning should be used when they:
• Are less than 1.5 m from a wall more than 2 m below the antenna.
• Use an external airborne connection between the base station and the system.
4.13.2.2 Recommendations for exposure of the public to the electromagnetic field
4.13.2.2.1 Magnetic absorption rate
Exposure  of  the  public  to  the  electromagnetic  field  from  DECT  sets  and  base  stations  is  measured
using the Specific Absorption Rate (SAR)  measuring  unit.  2  W/kg  is  the  SAR  limit  value  indicated  in
international recommendations and also in the European recommendation (1999/519/EC).
The  DECT  authorized  SAR  limit  value  is  2  W/kg  on  10  g  of  body  tissue  (local  SAR).  International
recommendations  include  a  safety  margin  for  the  public  and  take  account  of  possible  measuring
variations.
SAR values
• Set: as the average power emitted from a set is lower than 20 mW, the set is considered to comply
without  having  to  undergo  any  tests  (see:  EN  50371).  The  SAR  value  for  DECT  sets  is  not
significant.
• Base station: the local SAR (head and chest) on 10 g of body tissue for DECT base stations (e.g.:
4070) is lower than 0.5 W/kg (this is with an integrated omni-directional antenna).
4.13.2.2.2 Antennae characteristics
4.13.2.2.2.1 Integrated antennae
The following is a list of characteristics for integrated antennae:
• Bandwidth: 1.88 to 1.93 Ghz
• Impedance: 50 Ohms
• TOS: 1.5:1
• Gain: 3 dBi (maximum)
• Polarization: vertical (axis of the antenna)
• Width of the beam at 3 dB (vertical): 90º
• Radiation diagram: omni-directional in the horizontal plane.
4.13.2.2.2.2 External antennae
According to the ETSI EN 301 406 standard, DECT antenna gain is limited to 12 dB +/-3dB. In the case
of external directional antennae, if a minimum safety distance of 50 cm is respected, the SAR value is
the same as the value obtained in the case of an integrated omni-directional antenna (and therefore,
lower than: 0.5 W/kg).
4.13.2.2.3 Conformance perimeter for exposure of the public
• Integrated omni-directional antennae: no limit for the conformance perimeter
• External  antenna  (directional):  the  installation  must  allow  for  a  safety  perimeter  respecting  a
minimum distance of 50 cm.
Chapter 
4
Installation and Cabling
3EH21123USAA - Ed. 01  - April 2017 - Installation Manual 131/207