C 10
Alcatel Vacuum Technology France --- IPUP A100 Instruction manual
2 / 2
Operating mode
PUMP CONTROL MODES
Control Remote
disabled
= Autostart
Start / Stop the pump through RT1
switch.
Power start enabled
+
P
o
w
e
r
s
t
a
r
t
e
a
b
l
e
d
+
Control Remote
enabled
= Remote controlled (SPI 24V)
Start / Stop the pump through SPI
connector.
Control Remote
enabled
= Remote controlled (SPI 24V) Start / Stop the pump through SPI
connector.
Power start disabled
+
P
o
w
e
r
s
t
a
r
t
d
i
s
a
b
l
e
d
+
Control Remote
disabled
= Hand Held Display Module
controlled
Start / Stop the pump through hand
held display module.
PRIORITY CONTROL MODES
Control Remote
selection
Priority over
Enabled SPI > RS232
Disabled RS232 > Hand Held Display Module
RS232 > Autostart
REMOTE CONTROLLED
OPERATING MODE
Remote control of a single pump
through Amat SPI connector
The pump is monitored by the process tool in which it is installed and
is controlled remotely through the Amat SPI connector (see B 60).
Remote control of a single pump or
group of pumps through RS 232/485
serial link
The pump can be controlled through the RS 232/485 serial link (see
B 70 and C 90).