Publication 1747-UM655B-EN-P - June 2007
Configuring the DeviceNet Network 61
5. Select the Output tab.
6. Select M File in the Memory field.
7. Highlight the RediSTATION operator interface and click
AutoMap.
In this example, the output to the RediSTATION operator
interface appears in the M0 file for the device in slot 2 as word
0, bits 0…7. Recall from Chapter 3 that the indicator light is
output bit 0. Therefore, the address for the RediSTATION
indicator light is:
M0:2.0.0
8. Note the address assigned to this output in your system.
You enter this address in the example ladder logic program in
the following chapter.
After mapping, the
RediSTATION output
address appears
here.