Rockwell Automation Publication 750-PM001N-EN-P - February 2017 177
Drive Port 0 Parameters Chapter 3
File
Group
No. Display Name
Full Name
Description
Values
Read-Write
Data Type
APPLICATIONS
Fibers Function
1120 Fiber Control
Fiber Control
RW 16-bit
Integer
Controls the Sync and Traverse Fiber Application functions.
Bit 0 “Sync Enable” – Used in combination with an optional digital input to begin Synchronous speed change upon the falling edge of enable.
Bit 1 “Traverse Ena” – Used in combination with an optional digital input to enable/disable the speed traverse routine.
1121 Fiber Status
Fiber Status
RO 16-bit
Integer
Status of Sync and Traverse functions.
Bit 0 “Synch Hold” – Set when the Synchronous Speed change function is holding the speed reference constant. The speed will begin ramping to its setpoint upon
the falling edge of Sync Enable.
Bit 1 “Sync Ramp” – Set when the Synchronous Speed change function is ramping to its setpoint.
Bit 2 “Traverse On” – Set when the Traverse Speed function is varying the speed, either increasing or decreasing.
Bit 3 “Traverse Dec” – Set when the Traverse Speed function is decreasing the motor speed.
1122 Sync Time
Synchronize Time
The time in seconds to ramp from the “held speed reference” to the current speed
reference, after the Sync input is de-energized.
Units:
Default:
Min/Max:
Secs
0.0
0.0 / 3600.0
RW Real
1123 Traverse Inc
Traverse Increment
Sets the time period in seconds of increasing speed for the Fiber Traverse function.
Units:
Default:
Min/Max:
Secs
0.00
0.00 / 30.00
RW Real
1124 Traverse Dec
Traverse Decrement
Sets the time period in seconds of decreasing speed for the Fiber Traverse function.
Units:
Default:
Min/Max:
Secs
0.00
0.00 / 30.00
RW Real
1125 Max Traverse
Maximum Traverse
Sets the amplitude of the triangle wave speed modulation for the Fiber Traverse
function. The total speed variation will be twice this value, from speed ref plus Max
Traverse to speed ref minus Max Traverse.
Units:
Default:
Min/Max:
Hz
RPM
0.00
0.00 / P520 [Max Fwd Speed]
RW Real
Options
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Traverse Ena
Sync Enable
Default0000000000000000
Bit 1514131211109876543210
0 = Disabled
1 = Enabled
Options
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Traverse Dec
Traverse On
Sync Ramp
Sync Hold
Default0000000000000000
Bit 1514131211109876543210
0 = Disabled
1 = Enabled

Table of Contents

Other manuals for Allen-Bradley PowerFlex 750 Series

Questions and Answers: