34 Rockwell Automation Publication 1783-UM010C-EN-P - June 2019
Chapter 2 Industrial Firewall Use Cases
Figure 14 - Firewall Clock Settings Window
The equivalent CLI for this interface configuration is:
ntp server 192.168.254.20 prefer
To configure time synchronization for the FirePOWER component, complete
the following steps:
1. Click Configuration at the top left, then ASA FirePOWER
Configuration at the bottom left.
2. From the ASA FirePOWER Configuration pane, select
Local>System Policy.
3. For the policy labeled Initial System Policy, click the small pencil icon on
the right side to edit the policy.
4. On the left side of the edit window, click the
Time Synchronization option.
5. Next to Set My Clock, āVia NTP fromā and enter the IP address of the
NTP server to be the same as the one for the firewall component.
6. Click Save Policy and Exit.
7. To apply the changes, click the green checkbox to the right of the
Initial System Policy.