AT-MMC6000 Series Installation Guide
45
Set the DIP switches before the media converter is installed in the
AT-MMCR18 chassis because the switches are hidden afterward.
2. Refer to the AT-MMCR18 Chassis Installation Guide for installation
instructions.
3. Go to “Cabling the Provider Unit” on page 47.
Setting the
Provider Unit
DIP Switches
1. Set DIP switch 1 to the Down (CO) position as shown in Figure 16.
This configures the media converter as a Provider unit.
Figure 16. Provider Unit DIP Switch Position
DIP switches 2 - 4 configure the VDSL profile and are active only on
the Provider unit. It is important to configure the Provider unit VDSL
profile in the next step - Step 2. The Subscriber unit ignores its own
VDSL DIP switch settings.
2. Set DIP switches 2, 3, and 4 to the desired VDSL2 profile. Refer to
Table 2 on page 24 and Table 3 on page 25 for the profile definitions.
Go to “VDSL2 Configuration” on page 30 for more information.
3. Set DIP switch 5 to the desired SML setting: the Up (ON) position
enables SML; the Down (OFF) position disables SML.
Go to “Smart Missing Link (SML) Configuration” on page 30 and
“Smart MissingLink™ (SML)” on page 31 for an overview more
information concerning this feature.
Provider
(Down - CO position)