Technical Specifications
52
Table 10 lists environmental specifications for the AT-MMC6005-E.
Power Specifications
The following specifications apply to the DC power connector on the
media converter.
Safety and Electromagnetic Emissions Certifications
Table 10. Environmental Specifications - AT-MMC6005-E
Operating Temperature -20° C to 65° C (-4° F to 149° F)
Storage Temperature -40° C to 80° C (-40° F to 176° F)
Operating Humidity 5% to 90% non-condensing
Storage Humidity 5% to 95% non-condensing
Operating Altitude Range Up to 3,000 m (9,843 ft)
Table 11. Power Specifications
Input supply voltage 12 VDC
Input current (typical) 200 mA
Input current (maximum) 500 mA
Table 12. Safety and Electromagnetic Emissions Certifications
Safety UL60950-1, EN60950-1
Emissions (EMI)
FCC Class B, CISPR 22 Class B,
EN55032 Class B, C-TICK,
VCCI Class B
Immunity
EN55024, EN61000-3-2,
EN61000-3-3
Environmental Compliance
EU-RoHS compliant, WEEE
China RoHS compliant