9: PLC cycle completion
indication
10: Completion of readiness
for operation of inverter
(RDY)
11: Free stopping
12: Auto restart
13: Timing reaching
14: Counting reaching output
15: Set running time reaching
16: Torque reaching detection
17: CL current-limit action
18: Overvoltage stall
19: Inverter failure
20: External fault stopping
(EXT)
21: Uu1 undervoltage
stopping
22: CE communication alarm
23: Overload detection signal
(OLP)
24: Abnormality of analog
signal 1
25: Abnormality of analog
signal 2
26: Reserve
27: Reserve
28: Cut-to-length reaching,
level signal
29: Sleeping
30: Zero speed
31: Zero servo state (reserve)
32: Reverse control signal
(reserve)
33: Actual direction of
rotation
34: Reserve
35: Underload detection signal
(ULP)
P3.20 Reserve Reserve - - * 0414
P3.21 Reserve Reserve - - * 0415
P3.22 Reserve Reserve - - * 0416
P3.23 Reserve Reserve - - * 0417
P3.24
Relay 1
(TA/TB/TC)
Output function
selection
Relay output 0 to 35: the same with P3.19 19 × 0418
P3.25
Cut-to-length
reaching terminal
output hold time
Cut-to-length
output hold
0.0~3.0s 1.0s × 0419