[3-5] REGB Assy
1 Disconnect the one connector.
(CN12)
2 Remove the 2 screws and then remove the
Cover.
(BBZ30P080FTB)
3 Remove the REGB Assy.
P2P2
CN8
CN8
CN8
CN8
CN3
CN3
CN6301
CN6301
1
2
Screw tightening order
g Jumper wires styling
Jumper wires styling of this part must be attached according to the following instructions.
+ You should comply with product performance and safety standards of each country.
P2 to CN8
P4P4
CN3
CN3
P4 to CN3
P3P3
CN6301
CN6301
P3 to CN6301
Bind jumper wire with
cable tie position of
the line on the chassis.
Jumper wire pass the wire clip.
Jumper wire pass the wire clip.
Jumper wire pass the wire clip.
P2P2P4P4P3P3
CapacitorCapacitor
Put Jumper wire to the front
side of product than capacitor.
Cover
REGB
Assy
CN12CN12
Caution:
Before attaching Cover, you must
attach a thermal sheet to Cover.
Otherwise, the regulator in the
center will be damaged and the
product will break down.
Caution:
Before attaching Chassis, you must
attach a thermal sheet to Cover.
Otherwise, the regulator in the
center will be damaged and the
product will break down.
2
1
3
×2×2