Commissioning
18 Amatron+ BAG0082.2 10.10
5.3 Machine data entry
Select "Machine data" in main menu!
Page 1 in machine data menu (Fig. 17):
Enter the required tramline rhythm
(see tables Tabellen Fig. 18, Fig. 19).
Enter the interval tramline control
(see on page 21).
Enter the percentage application rate
increase in % (value for percentage sowing
rate change during work with
,
).
Calibrate the distance sensor (see
on page 22).
Fig. 17
Tramline rhythm
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 20 21 22 23 26 32 35
0 0 0 0 0 0 0 0 0 1 1 0 0 0 1 0 0 0 0 0 0 0 0 0
1 0 1 1 1 1 1 1 1 2 0 1 1 1 1 1 1 0 0 0 1 0 1
1 2 2 2 2 2 2 2 3 3 2 2 2 2 2 2 1 1 1 2 1 2
2 3 3 3 3 3 3 0 4 3 3 3 3 3 3 2 2 2 3 2 3
4 4 4 4 4 5 5 4 4 4 4 4 4 3 3 3 4 3 4
5 5 5 5 6 6 5 5 5 5 5 5 4 4 4 5 4 5
6 6 6 0 7 6 6 6 6 6 6 5 5 6 5 6
7 7 8 8 7 7 7 7 7 7 6 6 7 6 7
8 9 0 8 8 8 8 8 8 7 8 7 8
10 10 9 9 9 9 9 9 8 9 8 9
10 10 10 10 10 10 9 10
11 11 11 11 11 10 11
12 12 12 12 12
13 13 13 13
14 14 14
15 15
Tramline counter
Switching 15 starts no tramlines.
16
Fig. 18