Commissioning
Amatron+ BAG0082.2 10.10 27
8. Empty the collection bucket.
9.
Start the calibration test.
The electric motor doses the calibration
quantity to the collection bucket until the
acoustic signal is sounded.
10.
Terminate the calibration process
11. Weigh the seed caught in the collection
bucket(s) (take hopper weight into consid-
eration) and enter the weight (kg) in the
terminal.
The scales must weigh accurately.
Inaccuracies may cause deviations in
the actual sowing rate!
The AMATRON
+
calculates the required
calibration factor on the basis of the data entered
from the calibration test and sets the electric
motor to the correct speed.
Repeat the calibration process to
check the correct setting.